Overview |
![]() |
Requirements |
![]() |
Install Sensor Link |
![]() |
Install DRS |
![]() |
Install flowmeter |
![]() |
Troubleshoot |
---|---|---|---|---|---|---|---|---|---|---|
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Troubleshooting the Drum Rotation Sensor
The following section describes common and uncommon behaviors along with steps to solve any problems that may arise while using the Drum Rotation Sensor.

With the drum turning, each time a magnet passes the magnetic sensor, the LEDs should light up as follows:
POWER (ON) | YELLOW is ON solid, and blinks while the magnet passes |
---|---|
DIRECTION A > B | RED and GREEN both flash ON while magnet passes |
DIRECTION B > A | RED flashes ON while magnet passes |

If no lights are blinking on the sensor, we suggest that you check the Sensor Link Power LED to confirm that vehicleAll machines used as a means of production on a construction site or at a batch plant. power is present. If power is flowing to the Sensor Link, then the yellow light should be on. Additionally, check to make sure the Sensor Link to Drum Rotation Sensor cable is plugged in at both ends.

If the cable connections are properly connecting the sensor to the Sensor Link, then the LEDs for both FLOW 2 and FLOW 4 should flash when a magnet passes by the sensor.
What's next?
Now that the hardware assembly is installed, it must be configured to communicate with the TrackIt Web Console and TrackIt Android. Instructions regarding this process are found in the TrackIt Delivery Cycle Monitoring Software Configuration Guide
|
|